Enquiry now
banner

Product Range

Flexible Foam Dielectric Copper Feeder Cable 1/2″

Model: (1/2″ F CU) KCPL50PE12A1C

Specifications

Construction
Inner Conductor Copper Clad aluminum Wire 4.80+0.05 mm
Dielectric Foamed polyethylene Nominal 12.20+0.20 mm
Outer Conductor Corrugated Copper tube Nominal 13.80+0.15 mm
Jacket Standard black PE Nominal 15.80+0.20 mm
Mechanical Characteristics
Weight (+5%) Standard Jacket Nominal 0.19 kg/m
Minimum Bending Radius (Single) 70 mm
Minimum Bending Radius (Repeated) 125 mm
Number of bends, minimum (typical) 10(15)
Flat Plate Crush Resistance 1.30 kg/mm
Tensile strength 100Kgf
Environmental Specification
Operating Temperature Standard Jacket        -55℃~+85℃
Installation Temperature        -40℃~+60℃
Storage Temperature        -70℃~+85℃
       Standard Condition
Attenuation Ambient Temperature 20℃
Average Power, Ambient Temperature 40℃
Average Power, inner Counductor Temperature 100℃
Reference Standard IEC 61196-1

Electrical Characteristics
Max. Operating Frequency 8.8 GHz
DC Resistance Inner Conductor 1.48 Ω/km
Outer Conductor 2.90 Ω/km
Dielectric Strength DC 6,000V For 1 Min
Min. Insulation Resistance 10,000 MΩ.km
Velocity of Propagation 87±2%
Peak Power Rating 40 kW
Characteristic Impedance 50+1Ω
Capacitance 76 pF/m
Inductance 0.19 µH/m
Cut-off Frequency 8.8 GHz
Jacket Spark Test Voltage 8000 Vrms
PIM (IM3, 2 x 20W) ≤ -117 dBm (@ 900 MHz, 1800 MHz)
Return Loss 680~960 MHz ≤ -24.3 dB
1700~2200 MHz ≤ -24.3 dB
2200~2700 MHz ≤ -24.3 dB
3400~3800 MHz ≤ -20.8 dB

Frequency(MHz) AttenuationdB/100m
30 1.17
100 2.17
150 2.67
450 4.75
800 6.35
824 6.49
890 6.70
900 6.75
1000 7.2
1800 9.91
2000 10.70
2200 11.10
2300 11.54
2400 11.66
2500 11.95
2700 12.61
3000 13.44
3500 14.65
3600 14.80
3800 15.32

  • The attenuation may rise by 0.2%/ ℃ with rising temperature.
  • *Maximum attenuation value shall not exceed 105% of nominal value.
  • *Characteristic Impedance is the average value at the frequency range of 30 ~ 2400 MHz
  • *The above electrical figures should be guaranteed on condition that the cable is well fitted with our supplied connectors for good electrical matching at the cable length 100M.

Contact Kanhha Cables for your return loss specification of your required frequency band.

Client testimonial

Dedicated Customer Terms & An Agile Service

Our worldwide presence ensures the timeliness, cost efficiency and compliance adherence required to ensure your production timelines are met.

Download Brochures
Kanhha Cable

Request a Quote

Complete control over products allows us to ensure our customer receive the best quality price and service. we take great pride in everything that we do in our factory.