Enquiry now
banner

Product Range

Flexible Foam Dielectric Copper Feeder Cable 1/2″

Model: (1/2″ F CU) KCPL50PE12A2P

 

Specifications

Construction
Inner Conductor Copper Clad aluminum Wire 4.80+0.15 mm
Dielectric Foamed polyethylene Nominal 12.50+0.30 mm
Outer Conductor Corrugated Copper tube Nominal 13.70+0.30 mm
Jacket Standard black PE Nominal 15.70+0.30 mm
Mechanical Characteristics
Weight (+5%) Standard Jacket Nominal 0.19 kg/m
Minimum Bending Radius (Single) 70 mm
Minimum Bending Radius (Repeated) 125 mm
Number of bends, minimum (typical) 15(50)
Bending moment 5 Nm
Recommended hanger spacing 0.8 m
Flat Plate Crush Resistance 1.30 kg/mm
Tensile strength 1150N
Environmental Specification
Operating Temperature Standard Jacket        -40℃~+85℃
Installation Temperature        -25℃~+60℃
 

 

 

Storage Temperature

       -70℃~+85℃
RoHS Compliant
       Standard Condition
Attenuation Ambient Temperature 20℃
Average Power, Ambient Temperature 40℃
Average Power, inner Counductor Temperature 100℃
Reference Standard
UV resistance UL 1581 or IEC 60068-2-5


Electrical Characteristics
Max. Operating Frequency 8.8 GHz
 

DC Resistance

Inner Conductor 1.70 Ω/km
Outer Conductor 4.20 Ω/km
Dielectric Strength DC 6,000V For 1 Min
Min. Insulation Resistance 10,000 MΩ.km
Velocity of Propagation 88±2%
Peak Power Rating 40 kW
Characteristic Impedance 50+1Ω
Capacitance 76 pF/m
Inductance 0.19 µH/m
Cut-off Frequency 10.0 GHz
Jacket Spark Test Voltage 8000 Vrms
 

 

Return Loss

800~1000 MHz ≤ -26 dB
1700~1900 MHz ≤ -24 dB
1900~2200 MHz ≤ -24 dB
2200~2500 MHz ≤ -24 dB
2500~3000 MHz ≤ -24 dB

Frequency (MHz) Attenuation dB/100m Average Power (kW)
100 2.15 3.94
200 3.08 2.75
300 3.81 1.99
400 4.46 1.80
450 4.7 1.75
800 6.35 1.33
900 6.75 1.25
1000 7.2 1.18
1800 9.9 0.86
2000 10.5 0.81
2200 11.1 0.77
2500 11.95 0.73
2700 12.47 0.69
3000 13.2 0.65

  • The attenuation may rise by 0.2%/ ℃ with rising temperature.
  • *Maximum attenuation value shall not exceed 105% of nominal value.
  • *Characteristic Impedance is the average value at the frequency range of 30 ~ 2400 MHz
  • *The above electrical figures should be guaranteed on condition that the cable is well fitted with our supplied connectors for good electrical matching at the cable length 100M.

Contact Kanhha Cables for your specification of your required frequency band.

Client testimonial

Dedicated Customer Terms & An Agile Service

Our worldwide presence ensures the timeliness, cost efficiency and compliance adherence required to ensure your production timelines are met.

Download Brochures
Kanhha Cable

Request a Quote

Complete control over products allows us to ensure our customer receive the best quality price and service. we take great pride in everything that we do in our factory.