Flexible Foam Dielectric Aluminum Low Loss Feeder Cable 7/8″

Model: (7/8″ F Low Loss AL) KCPL50PE78L2P

 

Specifications

Construction
Inner Conductor Smooth copper tube Nominal 9.2+0.30 mm
Dielectric Foamed polyethylene Nominal 22.40+0.30 mm
Outer Conductor Corrugated aluminum tube Nominal 25.10+0.30 mm
Jacket Standard black PE Nominal 27.50+0.30 mm
Mechanical Characteristics
Weight (+5%) Standard Jacket Nominal 0.34 kg/m
Minimum Bending Radius (Single) 120 mm
Minimum Bending Radius (Repeated) 250 mm
Number of bends, minimum (typical) 15(30)
Bending moment 18Nm
Recommended hanger spacing 1.0 m
Flat Plate Crush Resistance 1.10 kg/mm
Tensile strength 1450N
Environmental Specification
Operating Temperature Standard Jacket -40℃~+85℃
Installation Temperature -25℃~+60℃
Storage Temperature -70℃~+85℃
RoHS Compliant
Standard Condition
Attenuation Ambient Temperature 20℃
Average Power, Ambient Temperature 40℃
Average Power, inner Counductor Temperature 100℃
Reference Standard
UV Resistance UL1581 or IEC 60068-2-5
Electrical Characteristics
Max. Operating Frequency 5.0 GHz
DC Resistance Inner Conductor 1.80 Ω/km
Outer Conductor 2.20 Ω/km
Dielectric Strength DC 8000V For 1 Min
Min. Insulation Resistance 10,000 MΩ.km
Velocity of Propagation 89±2%
Peak Power Rating 91 kW
Characteristic Impedance 50+1Ω
Capacitance 75 pF/m
Inductance 0.19 µH/m
Cut-off Frequency 5.2 GHz
Jacket Spark Test Voltage 8000 Vrms
Return Loss 800~1000 MHz ≤ -24 dB
1700~1900 MHz ≤ -23 dB
1900~2200 MHz ≤ -23 dB
2200~2500 MHz ≤ -21 dB
2500~3000 MHz ≤ -21 dB
Frequency (MHz) Attenuation dB/100m Average Power (kW)
200 1.75 4.83
450 2.71 2.88
800 3.68 2.09
900 3.89 1.98
1000 4.16 1.92
1800 5.83 1.35
2000 6.09 1.30
2200 6.47 1.26
2500 6.89 1.20
2700 7.58 1.13
3000 7.85 1.08
  • The attenuation may rise by 0.2%/ ℃ with rising temperature.
  • *Maximum attenuation value shall not exceed 105% of nominal value.
  • *Characteristic Impedance is the average value at the frequency range of 30 ~ 2400 MHz
  • *The above electrical figures should be guaranteed on condition that the cable is well fitted with our supplied connectors for good electrical matching at the cable length 100M.

Contact Kanhha Cables for your specification of your required frequency band.

Client testimonial

Dedicated Customer Terms & An Agile Service

Our worldwide presence ensures the timeliness, cost efficiency and compliance adherence required to ensure your production timelines are met.

Download Brochures
Kanhha Cable

Request a Quote

Complete control over products allows us to ensure our customer receive the best quality price and service. we take great pride in everything that we do in our factory.